TEL +81-44-877-8311TELPeriod of acceptance
weekdays from 9:00 a.m. to 5:00 p.m.(Japan time)

MENUCLOSE

HP-8701 | SH-3510

Transducer : HP-8701

HP-8701

The transducer generates powerful and stable vibrations even for cutting that requires high power,and the profile is designed to endure long-term use.

Specifications:HP-8701

Frequency 24kHz
Cord length Up to 10 m
Housing material SUS303 / Resin (Duracon)
Weight 1160g
Blade thickness 1.0mm

Applicable Materials

Thermoplastics

plate, sheet, film, and laminated material

Carbon prepregs

carbon fibers(CFRP)

Composite materials

polyethylene fiber, molded articles containing carbon or glass fibers(GFRP)

Rubber 20t

vulcanized latex, non-vulcanized latex, sheeting material, and tube

Standard Tools

  • FB-4221-9

    FB-4221-9

  • FB-0231-6L

    FB-0231-6L

  • FB-0131-6L

    FB-0131-6L

Option

  •  Torque driver

    Torque driver[9N/m]

  • bit

    bit[M4]

Click here to download the dimensions and catalogs

Click here to apply for a test cut and Inquiries

Apply for a test cutting by phone

TEL +81-44-877-8311

Period of acceptance weekdays from 9:00 a.m. to 5:00 p.m.(Japan time)

Oscillator:SH-3510

Upgraded: Connection with PLC is now available

Factory improvement through DX/loT requires connection with various controllers and connection with PLC is now available besides the conventional relay control by ON/OFF switching. Standard installation of analog signal output for the load/amplitude and additional digital signals for each oscillation frequency/error type allow outputting more detailed data now.

Specifications:SH-3510

Frequency adjustment Automatic tracking type
Maximum output 500W
Output adjustment Step-less continuously variable type
Power requirement Single phase
200 VAC, 50/60 Hz
Power consumption  1000VA
Outer dimension (mm)  300W × 400D × 200H
Weight  11kg
Function  Detection of error cause
External device connection function Input Oscillator ON/OFF, Amplitude adjustment. Error recovery
Output

DC analog output. Frequency pulse output.

Load threshold warning, Power supply status monitor,Error detection

 

Transducer combined with SH-3510

  • Machine / robot-mounted type
  • Manual-type hand piece
Combination transducers Frequency Applicable materials
Machine / robot-mounted type HP-8701 HP-8701 24kHz ThermoplasticsCarbon prepregComposite materials Rubber 20t
Machine / robot-mounted type HP-2000 HP-2000 20kHz ThermoplasticsPrepregRubber 15t
Machine / robot-mounted type SF-3110 SF-3110 20kHz ThermoplasticsPrepregRubber 15t
Machine / robot-mounted type SF-8500RR SF-8500RR 22kHz Thermoplastics Composite materialsRubber 15t

Products

PAGETOP